IT / EN
Skip to Content
VICTRIX SUPERIOR 32 X 2 ErP
Code 3.025506
Heat output kW 32,0
Dimensions (HxWxD) mm 830 x 440 x 350
Type for heating only
Modulating heat output 12,5 - 100%

A

Wall-hung condensing boiler, for heating only .
32 kW heat output.
For heating only version of VICTRIX SUPERIOR 32 2 ErP,  ideal for simultaneous domestic hot water withdrawals when coupled with separate storage tanks with capacity from 80 up to 2000 liters, VICTRIX SUPERIOR 32 2 ErP can be connected to thermal solar systems with forced circulation.
The modulating pump succeed in important savings of electrical consumption by automatically adjusting the operation according to the different system terms of use.
The wide and functional liquid crystals backlit display, allows an easy and immediate visualization of the main functioning information. Thanks to the electronics it is possible to connect the boiler to optional kits for the climatic thermoregulation. Certified to be installed indoor and outdoor in partially sheltered areas thanks to the IPX5D protection. The boiler is supplied with -3° C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX SUPERIOR 32 2 ErP belongs to class 5, the most environmentally-friendly one, as established by the European standards (UNI EN 297 e 483).
When  large power amount is required, VICTRIX SUPERIOR 32 2 ErP can be installed in cascade (up to 3 appliances), thanks to appropriate optional kits.

Solar system integration
Modulating pump
Possible installation in cascade
Thermoregulation
Super CAR (weekly thermostat and modulating remote control)       Code 3.016577
Available for: All Superior models and VICTRIX Zeus, HERCULES, ZEUS kW, AVIO kW, NIKE Mini 28 kW Special.

Class of device V* or VI
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%

* as standard

Cascade and zone regulator kit       Code 3.015244
ON-OFF adjustment, modulation and malfunctions of the VICTRIX PRO in cascade (max 8). It can manage any climatic zone regulators in the system (max 3 plus 1 dedicated to the hot tap water circuit).
CARV2 (weekly thermostat and modulating remote control)       Code 3.021395

Available for all models.

Class of device V* or VI
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%

*as standard

CARV2 WIRELESS (radio wave weekly thermostat and modulating remote control)       Code 3.021623
Available for: VICTRIX, VICTRIX TT, VICTRIX MAIOR TT, VICTRIX X, MAIOR EOLO, NIKE Mini 28 kW Special, MINI NIKE/EOLO, MINI NIKE/EOLO X and NIKE/EOLO Star.

Class of device V* or VI
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%

* as standard

CRONO 7 (weekly digital chronothermostat)       Code 3.021622

Available for all models.

Class of device IV* or VII
Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* as standard

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)       Code 3.021624

Available for all models.

Class of device IV* or VII
Contribution to the environmental heating energy efficiency 2%* or 3,5%

* as standard

External probe       Code 3.014083
Allows at the boiler to functioning at a variable temperature according to the climatic conditions. Available for all models, except NIKE/EOLO Star.

Class of device II*
Contribution to the environmental heating seasonal energy efficiency 2%*

* as standard

GSM telephonic control       Code 3.017182

For buildings not equipped with telephone network. Available for all Immergas models.

Telephonic control       Code 3.013305

For buildings equipped with telephone network. Available for all Immergas models.

Control box for pumps and zone       Code 3.011668
Maximum three zones.
Available for: all Superior models and VICTRIX TT, VICTRIX Zeus, HERCULES, ZEUS kW, AVIO kW, MAIOR EOLO and NIKE Mini 28 kW Special.
Relay board kit       Code 3.015350
Allows interface between zone valves and CAR or Super CAR, to send an alarm signal, to manage external pump etc.
Available for: all Superior models and VICTRIX, VICTRIX TT, VICTRIX X, VICTRIX R, HERCULES, MAIOR EOLO and EOLO Extra kW.
Safety thermostat kit       Cod. 3.019229

For VICTRIX Superior TOP/X, VICTRIX, VICTRIX X and VICTRIX R.

Flue systems
Horizontal concentric complete kit Ø 60/100 with swivel terminal       Code 3.024267
Max lenght 9,9 m.
For condensing boiler < 35 kW except HP models.
Horizontal concentric complete kit Ø 60/100 with swivel terminal       Code 3.024267
Max lenght 9,9 m.
For condensing boiler < 35 kW except HP models.
Concentric horizontal complete kit Ø 60/100       Code 3.012000

Max lenght 12,9 m.
For condensing boiler < 35 kW.

Horizontal concentric complete kit Ø 60/100 Short       Code 3.024598

Max lenght 11,9 m.
For condensing boiler < 35 kW.

Concentric vertical complete kit Ø 60/100 (red ocher colour)       Code 3.016833

Lunghezza 956 mm, estensione massima 12,9 metri.
Utilizzabile solo per caldaie a condensazione < 35 kW.

Twin pipes complete kit Ø 80/80       Code 3.012002

For condensing boiler < 35 kW.

Terminal vertical outlet kit Ø 80       Code 3.015256

For condensing boiler < 35 kW.

Anti-wind vertical terminal kit Ø 80       Code 3.021721

For condensign boiler < 35 kW.

Options
DIM 3 ZONES ErP       Cod. 3.025608
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
High energetic efficiency thanks to class A pumps. Hydraulic manifold, 3 low consumption pumps and electronic board.
DIM H-LT ErP       Code 3.025609
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
High energetic efficiency thanks to class A pumps. Hydraulic manifold, 2 low consumption pumps, 1 mixing valve and electronic board.
DIM H-2LT ErP       Code 3.025610

Kit for mixed systems with 2 low temperature zones and 1 high temperature zone.
High energetic efficiency thanks to class A pumps. Hydraulic manifold, 3 low consumption pumps, 2 mixing valves and electronic board.

DIM BASIC ErP      Code. 3.025606
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
Hydraulic manifold and 1 low-consumption pump.
DIM 2 ZONES ErP       Code 3.025607
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
Hydraulic manifold, 2 low-consumption pumps and electronic board.
Anti-freeze protection kit -15 °C for VICTRIX Superior ErP/X       Code 3.015348

Per protezione antigelo fino a -15°C.
Per VICTRIX SUPERIOR ErP/PLUS ErP.

Magnetic cyclone filter kit       Code 3.024176

Magnetic cyclone filter kit to prevent system ferrous residual (only for internal installation).
Available for: VICTRIX Superior TOP/X, VICTRIX TT, VICTRIX Zeus kW, VICTRIX Zeus Superior kW, VICTRIX and VICTRIX X.

2 litres additional expansion vessel       Code 3.018433
Available for: ZEUS kW, ZEUS Superior kW, VICTRIX Zeus Superior kW, AVIO kW, VICTRIX Zeus, VICTRIX Superior TOP/X, MAIOR EOLO, MINI EOLO/NIKE and MINI EOLO/NIKE X.
Shut off knobs       Code 3.5324

For wall-hung outdoor boilers.

Shut off knobs with filter       Code 3.015854
Available for: ZEUS kW, ZEUS Superior kW, VICTRIX Zeus Superior kW, AVIO kW, VICTRIX Zeus, VICTRIX Superior TOP/X, VICTRIX, VICTRIX X, VICTRIX R, EOLO Extra kW HP and MAIOR EOLO.
All-purpose connection kit for wall-hung combi boilers       Code 3.011667

For wall-hung combi boilers and also for wall-hung with built-in storage tank.

Cover kit for VICTRIX Superior 32 ErP/ 32 X ErP    Code 3.017209

Per funzionamento in luoghi parzialmente protetti.
Per caldaie MAGIS VICTRIX ErP, VICTRIX SUPERIOR ErP, VICTRIX SUPERIOR 32 PLUS ErP.

Thermoregulation
Flue systems
Options
Related products
VICTRIX SUPERIOR 32 2 ErP
Wall-hung combi condensing boiler with "Aqua Celeris"

OPEN PRODUCT

UB INOX SOLAR 200 ErP
Inox Storage Tank Unit for production of domestic hot water and built-in solar circuit

OPEN PRODUCT

 
CONTACT US
 
 
QUALITY IN SERVICES
MADE IN ITALY
50 years of experience
OVER 6 MILLION BOILERS INSTALLED