63,5 kW heat output.
Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO ErP boiler is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO ErP can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO 68 2 ErP belongs to class 5, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).
- Instruction booklet and warning
- Installation in Cascade instruction book
- Technical sheet
- .dwg drawing
- File BIM .ifc
- File BIM .rfa
- EC Certificate

This is a modulating control unit that serves to optimize climatic management of the temperature in rooms. It can only be used on systems with a single temperature control.

If the cascade and zone regolator is not install inside an electrical box.
Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.

To be used when external probe as standard in outdoor unit is not correctly exposed.
Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%
* default settings

Connected to the cascade and zone regulator, it optimizes energy consumption by correcting the delivery temperature to the system for smooth temperature function
Positioned on the delivery pipe, after the hydraulic separator, it allows the cascade and zone regulator to control system temperature as well as that of any mixed zones.

ON/OFF room thermostat.
Class of device IV* or VII
Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%
* default settings

ON/OFF room thermostat.
Class of device IV* or VII
Contribution to the environmental heating energy efficiency 2%* or 3,5%
* default settings

Zone manager kit Code 3.015264

Modulating room thermostat Code 3.015245
Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone. Allows control of room temperature only.



For the storage tank unit managed as a zone (with a circulator) and connected to the cascade regulator (without external 3-way valve). For solar installations managed with cascade and zone regulator two probes are necessary.

Terminal vertical outlet outdoor kit Ø 80 Code 3.024295
For VICTRIX PRO.

Horizontal kit Ø 80 (to discharge in the chimney) Code 3.015254
For VICTRIX PRO.

Terminal horizontal outlet kit Ø 80 (to discharge horizontally) Code 3.015255
For VICTRIX PRO.

Horizontal concentric kit Ø 80/125 Code 3.030782
for VICTRIX PRO 35-55-68-80 ErP.


Terminal vertical outlet kit Ø 80 Code 3.015256
For condensing boiler < 35 kW.

Exhaust manifold kit 2 VICTRIX PRO 80/100/120 Ø 200 with flue lock Code 3.024281
Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.

Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.








Insulation as standard.




Insulation as standard.


Inclusive of granulate.