Wall hung, modular condensing boiler for heating only.
73 kW heat output.
Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO ErP boiler is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO ErP can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO 80 2 ErP belongs to class 5, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).
Wide modulating heat output
Ideal for energy efficiency upgrade
Possible installation in cascade
Thermoregulation
Remote control for single VICTRIX PRO Code 3.020358
This is a modulating control unit that serves to optimize climatic management of the temperature in rooms. It can only be used on systems with a single temperature control.
Cascade and zone regulator kit Code 3.015244
ON-OFF adjustment, modulation and malfunctions of the VICTRIX PRO in cascade (max 8). It can manage any climatic zone regulators in the system (max 3 plus 1 dedicated to the hot tap water circuit).
Wall box kit for cascade and zone regulator Code 3.015265
If the cascade and zone regolator is not install inside an electrical box.
System delivery probe kit for the boiler VICTRIX PRO Code 3.024245
Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.
External probe Code 3.015266
To be used when external probe as standard in outdoor unit is not correctly exposed.
Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%
* default settings
Tele-management kit 2.0 Code 3.029832
Can be combined exclusively with the cascade and zone regulator for connection to an ethernet network or via router/modem to an ADSL line for connection to a remote system.
External probe (for installation in battery) Code 3.024511
Connected to the cascade and zone regulator, it optimizes energy consumption by correcting the delivery temperature to the system for smooth temperature function
Flow probe Code 3.015267
Positioned on the delivery pipe, after the hydraulic separator, it allows the cascade and zone regulator to control system temperature as well as that of any mixed zones.
CRONO 7 (weekly digital chronothermostat) Code 3.021622
ON/OFF room thermostat.
Class of device IV* or VII
Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%
* default settings
CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Code 3.021624
ON/OFF room thermostat.
Class of device IV* or VII
Contribution to the environmental heating energy efficiency 2%* or 3,5%
* default settings
Zone manager kit Code 3.015264
Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone, and allow remote control of the cascade and zone regulator.
Modulating room thermostat Code 3.015245
Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone. Allows control of room temperature only.
Solar collector probe Code 3.019374
To be used to manage the solar system coupled to thermal plants using the cascade and zone regulator.
Solar collector probe Code 3.019374
To be used to manage the solar system coupled to thermal plants using the cascade and zone regulator.
Storage tank sensor kit (for managing the storage tank as a zone) Code 3.015268
For the storage tank unit managed as a zone (with a circulator) and connected to the cascade regulator (without external 3-way valve). For solar installations managed with cascade and zone regulator two probes are necessary.
Flue systems
Terminal vertical outlet outdoor kit Ø 80 Code 3.024295
Horizontal kit Ø 80 (to discharge in the chimney) Code 3.015254
Terminal horizontal outlet kit Ø 80 (to discharge horizontally) Code 3.015255
Horizontal concentric kit Ø 80/125 Code 3.030782
for VICTRIX PRO 35-55-68-80 ErP.
Vertical concentric kit Ø 80/125 Code 3.015243
Terminal vertical outlet kit Ø 80 Code 3.015256
For condensing boiler < 35 kW.
Exhaust manifold kit 2 VICTRIX PRO 80/100/120 Ø 200 with flue lock Code 3.024281
Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.
Additional exhaust manifold kit VICTRIX PRO 80/100/120 Ø 200 with flue lock Code 3.024282
Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.
Extension pipe Ø 200 kit 0,5 m long for flue manifold Code 3.024663
For installations in central heating systems with VICTRIX PRO.
Extension pipe Ø 200 kit 1 m long for flue manifold Code 3.024662
For installations in central heating systems with VICTRIX PRO.
Options
Safety kit single boiler VICTRIX PRO Code 3.023949
The kit includes thermometer, thermometer holder, lock, thermostatwith manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure. Insulation as standard.
Three-way valve kit connection to a separate storage tank VICTRIX PRO Code 3.023950
The kit includes the storage tank probe. The power supply is 230 Vac.
Insulation as standard.
Hydraulic manifold kit for VICTRIX PRO 80/100/120 Code 3.023952
Specially sized for large thermal systems with high water content. Equipped with sludge collection filter on the return pipe.
Insulation as standard
IPX4D protection box kit for single boiler safety kit VICTRIX PRO Code 3.024028
Hydraulic manifold kit DN 100 for 2 VICTRIX PRO 80/100/120 in cascade Code 3.023959
Kit to connect 2 VICTRIX PRO 80/100/120 in cascade installation; it includes a 2 way interception valve, a 3-way interception valve and a non-return valve for each generator.
Insulation as standard.
Hydraulic manifold kit DN 100 for additional VICTRIX PRO 80/100/120 in cascade Code 3.023960
In combination with kit 3.023959 serves to connect from 3 to 5 VICTRIX PRO 80/100/120 boilers in cascade installation (one kit required for each additional boiler); includes a 2-way interception valve, a 3-way interception valve and a non-return valve.
Insulation as standard.
Safety kit DN 100 for VICTRIX PRO 80/100/120 in cascade Code 3.023961
The kit includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure.
Insulation as standard.
IPX4D protection box kit for cascade safety kit Code 3.024038
Hydraulic separator for 200 kW installations Code 3.021377
Separator with G2 ½" threaded connectors.
Insulation as standard.
Hydraulic separator for 400 kW installations Code 3.021378
Separator with G2 ½" threaded connectors on boiler side - DN 100 on system side.
Insulation as standard.
Hydraulic separator for 350 kW installations Code 3.023965
Separator with threaded connectors - DN 100.
Insulation as standard.
Hydraulic separator for 600 kW installations Code 3.023962
Separator with threaded connectors - DN 100.
Insulation as standard.
Condensate neutralizer kit Code 3.019857
Necessary to neutralize the acidity of the condensation. Inclusive of granulate.
Granulate for condensate neutralizer VICTRIX PRO Code 3.019865
Extra granulate for condensation passivator kit code 3.019857.
Condensate neutralizer kit for cascade installation Code 3.019464
Necessary to neutralize the acidity of the condensation.
Inclusive of granulate.
Condensate discharge pump kit Code 3.020002